Requirements of anchorage for prestressed CFRP plate system

When prestressed CFRP plate is used to reinforce reinforced concrete structure, the anchorage end and anchorage end of anchorage should have at least one end.

1.When prestressed CFRP plate is used to reinforce reinforced concrete structure, the anchorage end and anchorage end of anchorage should have at least one end.

 prestressed cfrp plate system

Plane sketch map of tensioning front anchorage

1- tensioning anchor; 2- thrust frame; 3- guide screw; 4- tensioning support; 5- fixed end positioning board; 6- fixed end anchor; 7-M20 glue anchor bolt; 8-M16 bolt; 9- carbon fiber composite board; 10-M12 bolt; 10-M12 bolt; 11- reserved hole. After completion of tension, M20 gum bolt was implanted after tensioning completion.


prestressed cfrp lamiante system


Plane sketch map of tensioning completion anchorage

1- tension anchorage; 6- fixing anchorage; 7-M20 anchor bolt; 9- carbon fiber composite plate


2.The anchorage device for prestressed carbon fiber reinforced plastic plate can be used as plate anchorage, or small toothed rack anchorage (sharp teeth, toothed anchor and round tooth rack).


3. when designing the flat plate anchorage, the thickness of the cover plate and the base plate shall be no less than 14mm and 10mm, respectively, and the nominal diameter of the pressure bolts shall not be less than 22mm.


4.The design structure of tooth anchorage teeth, the tooth depth should be 0.3mm~0.5mm, tooth spacing should be 0.6mm~1.0mm. In order to prevent the sharp tooth anchorage will cut the prestressed carbon fiber composite plate, the anchor should be chamfered teeth in place.


prestressed cfrp lamiante system


5.when designing the anchor for the round tooth, the depth of the tooth should be 0.3mm~0.5mm, and the spacing between the teeth should be 0.6mm~1.0mm. In order to prevent the prestress carbon fiber composite board from friction with the anchorage at the exit of the anchorage, the anchorage of the anchorage should be parallel to the tension direction of the prestressed CFRP plate at the end of the anchorage.


prestressed cfrp lamiante system


6.The opening position and diameter of the anchorage shall be determined according to the actual project.


Horse Construction Recommended Products

You can find anything here you are in need of, have a trust trying on these products, you will find the big difference after that.

HM-1.2T Unidirectional Carbon Fiber Strip

High strength carbon fiber reinforced polymer (CFRP) strip / laminate / plate for structural strengthening and concrete repair

See more >

HM-MJ50/100 Prestressed CFRP Plate System

Prestressed carbon fiber reinforced polymer(CFRP) plate for slab, beam strengthening to increase stiffness, reduce distortion and deflection of members, reduce the cracks, avoid and stop cracking.

See more >

HM-120CP CFRP Strip Adhesive

High strength carbon fiber reinforced polymer plate adhesive for applying CFRP laminate/strip/plate on the structural members

See more >

Back
Top
Close